Download Print this page

Mitsubishi Electric MELDAS 60 Series Parameter Manual page 33

Cnc
Hide thumbs Also See for MELDAS 60 Series:

Advertisement

Alarm No.
Name
Over regeneration
73
Regenerative
74
resistor overheat
75
Overvoltage
External emergency
76
stop setting error
77
Power module
overheat
7F
Drive unit power
supply restart
request
80
Detector converting
unit 1: Connection
error
Detector converting
81
unit 1:
Communication
error
Detector converting
83
unit 1: Judgment
error
Detector converting
84
unit 1: CPU error
85
Detector converting
unit 1: Data error
86
Detector converting
unit 1: Magnetic pole
error
88
Watchdog
89
Detector converting
unit 2: Connection
error
1. List of Alarms
1.3 Servo spindle Alarms
Over-regeneration detection level became over 100%. The
regenerative resistor is overloaded.
Thermal protection function of the regenerative resistor, has started
its operation.
PN bus voltage in main circuit exceeded the allowable value.
As for the external emergency stop settings, the setting on the rotary
switch and the parameter setting are mismatched.
Thermal protection function in the power module has started its
operation.
A mismatch of program mode selection was detected. Turn the drive
unit power ON again.
A connection error was detected between the analog output linear
scale and the unit MDS-B-HR that is used in a linear servo system.
A communication error was detected between the serial output linear
scale and the unit MDS-B-HR that is used in a linear servo system.
Judgment of the linear scale analog frequency failed in the unit
MDS-B-HR that is used in a linear servo system.
A CPU error was detected in the unit MDS-B-HR that is used in a
linear servo system.
A data error was detected in the unit MDS-B-HR that is used in a
linear servo system.
An error was detected in the magnetic pole of the unit MDS-B-HR
that is used in a linear servo system.
The system does not operate correctly.
A connection error was detected between the analog output linear
scale and the unit MDS-B-HR in a servo system. In a spindle
system, the initial communication with MDS-B-PJEX failed.
I - 19
Meaning

Advertisement

loading