Download Print this page

Mitsubishi Electric MELDAS 60 Series Parameter Manual page 357

Cnc
Hide thumbs Also See for MELDAS 60 Series:

Advertisement

No.
Items
3380
SP180 VGSD
(PR)
3381
SP181 VCGS
(PR)
3382
SP182 VCSS
(PR)
3383 SP183 SYNV
3384
SP184 FFCS
(PR)
3385 SP185 SINP
3386
SP186 SODR
(PR)
3387
SP187 IQGS
(PR)
8. Spindle Parameters
8.3 MDS-B-SP/SPH, MDS-C1-SP/SPH
Spindle
Set the speed loop delay advance gain in
synchronous
spindle synchronous mode.
speed loop
When this parameter is set to "0", PI control
gain delay
is applied.
advance term
Spindle
Set the magnification of speed loop
synchronous
proportional gain with respect to SP178
Target value of
(VGSP) at the maximum speed defined in
variable speed
SP017 (TSP) in spindle synchronous mode.
loop
proportional
gain
Spindle
Set the speed when the speed loop
synchronous
proportional gain change starts in the
Change
spindle synchronous mode.
starting speed
of variable
speed loop
proportional
gain
SP178×
(SP181/100)
Spindle
For changeover from the speed loop to the
synchronous
position loop in the spindle synchronous
Sync match-
mode, set a speed command error range for
ing speed
output of the synchronous speed matching
signal.
Spindle
Set the acceleration rate feed forward gain in
synchronous
the spindle synchronous mode.
Acceleration
This parameter is used only with the SPJ2.
rate feed
forward gain
Spindle
Set the position error range for output of the
synchronous
in-position signal in the spindle synchronous
In-position
mode.
width
Spindle
Set the excessive error width in the spindle
synchronous
synchronous mode.
Excessive
error width
Spindle
Set the magnification of current loop gain
synchronous
(torque component) in the spindle
Current loop
synchronous mode.
gain magnifi-
cation1
Details
Proportional gain
SP178
Speed
SP182
SP017
II - 261
Setting
Standard
range
setting
0 to 1000
15
(0.1 1/s)
0 to 100 (%) 100
0 to 32767
0
(r/min)
0 to 1000
20
(r/min)
0 to 1000
0
(%)
1 to 2880
16
(1/16°)
1 to 32767
32767
( pulse)
(1 pulse
=0.088°)
1 to 1000
100
(%)

Advertisement