3. Program Error
(The bold characters are the message displayed in the screen.)
These alarms occur during automatic operation‚ and the causes of these alarms are mainly program errors
which occur‚ for instance‚ when mistakes have been made in the preparation of the machining programs or
when programs which conform to the specification have not been prepared.
Error No.
P 10
EXCS. AXIS No.
The number of axis addresses
commanded in the same block exceeds
the specifications.
P 11
AXIS ADR. ERROR
The axis address commanded by the
program and the axis address set by the
parameter do not match.
P 20
DIVISION ERROR
An axis command which cannot be
divided by the command unit has been
issued.
P 29
NOT ACCEPT CMND
• The normal line control command
(G40.1, G41.1, G42.1) has been
issued during the modal in which the
normal line control is not acceptable.
• 2-part system synchronous thread
cutting command was issued during a
modal for which a 2-part system
synchronous thread cutting command
cannot be issued.
P 30
PARITY H
The number of holes per character on the
paper tape is even for EIA code and odd
for ISO code.
P 31
PARITY V
The number of characters per block on
the paper tape is odd.
P 32
ADDRESS ERROR
An address not listed in the specifications
has been used.
P 33
FORMAT ERROR
The command format in the program is
not correct.
3. Program Error
Details
I - 63
Remedy
• Divide the alarm block command into two.
• Check the specifications.
• Revise the axis names in the program.
• Check the program.
• Check the program.
• Check the paper tape.
• Check the tape puncher and tape reader.
• Make the number of characters per block on
the paper tape even.
• Set the parameter parity V selection OFF.
• Check and revise the program address.
• Check and correct the parameters values.
• Check the specifications.
• Check the program.

Advertisement