8.1 MDS-B-SP/SPH, SPJ2 Spindle Base Specifications Parameters
#
Items
3021 sori
Orientation rotation
speed
3022 sgear
Encoder gear ratio
3023 smini
Minimum rotation
speed
3024
sout
Spindle connection Set the type of the spindle to be connected.
(PR)
3025 enc-on
Spindle encoder
3026
cs_ori
Selection of
winding in
orientation mode
3027
cs_syn
Selection of
winding in spindle
synchronous mode
3028 sprcmm
L system tap cycle
spindle forward run/
reverse run M
command
8. MDS-B-SP/SPH, SPJ2 Spindle Parameters
Set the spindle orientation rotation speed.
Set the rotation speed for when the spindle
rotates at the constant rotation speed.
Set the gear ratio of the spindle to the
encoder.
Set the minimum rotation speed of the
spindle.
If an S command instructs the rotation
speed below this setting, the spindle rotates
at the minimum rotation speed set by this
parameter.
0: No connection with the spindle
1: Serial connection (bus)
2 to 5: Analog output
Set connection information of the spindle
encoder.
0: No connection
1: Spindle connection (Spindle encoder
connection check function valid.)
2: Serial connection of encoder
0: Perform orientation using the winding
selected when the orientation
command is issued.
1: Use winding L whenever the orientation
command is issued.
0: The winding H/L is selected by the
actual spindle motor rotation speed
(calculated from commanded rotation
speed) when spindle synchronous
control starts. (The winding is not
switched during synchronous control.
The control is carried out with the
winding selected at start.)
If the actual spindle motor rotation
speed is less than SP020, the winding L
is selected, and if more than the value,
the winding H is selected.
1: Use winding H whenever the spindle
synchronous command is issued.
Set the M code of the spindle forward
run/reverse run command.
High-order three digits:
Low-order three digits:
II - 210
Details
The spindle
forward run
command's M
code is set.
The spindle
reverse run
command's M
code is set.
Setting range (Unit)
0 to 32767 (r/min)
0: 1/1
1: 1/2
2: 1/4
3: 1/8
0 to 32767 (r/min)
0 to 5
0 to 2
0/1
0/1
0 to 999999

Advertisement