2.3 Axis Parameters
Set up the parameter required for each axis.
#
Item
8201 AX. RELEASE
8202 OT-CHECK OFF
8203 OT-CHECK-CANCEL When the simple absolute position method (#2049
8204 OT-CHECK-N
8205 OT-CHECK-P
8206 TOOL CHG. P
8207 G76/87 IGNR
(For M system only)
8208 G76/87 (–)
(For M system only)
8209 G60 SHIFT
(For M system only)
2. Machining Parameters
2.3 Axis Parameters
Contents
Select the function to remove the control axis from
the control target.
0: Control as normal.
1: Remove from control target.
Select the stored stroke limit II function set in #8204
and #8205.
0: Stored stroke limit II valid
1: Stored stroke limit II invalid
type is 9) is selected‚ the stored stroke limits I, II (or
IIB) and IB will be invalid until the first zero point
return is executed after the power is turned ON.
0: Stored stroke limit II valid (according to
#8202)
1: Stored stroke limit II invalid
Note: Temporary cancel of #8203 soft limit affects
all the stored stroke limits.
This sets the coordinates of the (-) direction in the
moveable range of the stored stroke limit II or the
lower limit coordinates of the prohibited range of
stored stroke limit IIB.
If the sign and value are the same as #8205, the
stored stroke limit II (or IIB) will be invalid.
If the stored stroke limit IIB function is selected, the
prohibited range will be between two points even
when #8204 and #8205 are set in reverse.
When II is selected, the entire range will be
prohibited.
This sets the coordinates of the (+) direction in the
moveable range of the stored stroke limit II or the
upper limit coordinates of the prohibited range of
stored stroke limit IIB.
Set the coordinates of the tool change position for
G30. n (tool change position return).
Set with coordinates in the basic machine
coordinate system.
Select the shift operation at G76 (fine boring) and
G87 (back boring).
Specifies the shift direction at G76 and G87.
Set the last positioning direction and distance for a
G60 (uni-directional positioning) command.
II - 12
Setup range (unit)
0/1
0/1
0/1
±99999.999 (mm)
±99999.999 (mm)
±99999.999 (mm)
0: Shift effective
1: No shift
0: Shift to (+) direction
1: Shift to (-) direction
±99999.999 (mm)

Advertisement