Items
1121 edlk_c
Edit lock C
1122
pglk_c
Program
(PR)
display lock
1123 origin
Origin zero
inhibition
1124 ofsfix
Fix tool wear
compen-
sation number
1125 real_f
Actual
feedrate
display
1126 PB_G90
Playback G90 Specify whether the playback movement amount
1127 DPRINT
DPRINT
alignment
5. Base Specifications Parameters
(SETUP PARAM 1. 5/15)
Details
Specify whether to prohibit editing of program Nos.
9000 to 9999.
Note: If #1122 is set to 1 or 2, 1 will be set in #1121
when the power is turned ON.
The display and search of program Nos. 9000 to
9999 can be prohibited. Specify whether to prohibit
display and search.
0: Display and search is possible.
1: Program details are not displayed.
2: Program details are not displayed‚ and
operation search is prohibited.
The program details will not be displayed‚ but the
program No. and sequence No. will display in the
prohibited state.
Note: If #1122 is set to 1 or 2, 1 will be set in #1121
when the power is turned ON.
Select whether to use the origin zero function.
Specify whether to automatically increment the
offset No. by 1 with the input or to display the No. as
it is in the setting on the tool offset screen.
0: Increment the # No. by 1 when the input key
is pressed. (Same as general parameters)
1: # No. does not change even if INPUT key is
pressed.
When making settings in sequence‚ 0 is handier.
When changing and setting repeatedly while
adjusting one offset value‚ 1 is handier
Specify the feedrate display on the monitor screen. 0: Command speed
when performing playback editing is to be an
absolute value or incremental value.
Specify the alignment for printing out with the
DPRINT function.
0: No alignment‚ data is printed with left
justification.
1: Align the minimum digit and output.
II - 41
Setting range (unit)
0: Editing possible
1: Editing prohibited
0 to 2
0: Use
1: Do not use
0/1
1: Real movement
feedrate
0: Incremental value
1: Absolute value
0/1