No.
Items
3400
SP200 FFC1
(PR)
3401
SP201 FFC2
(PR)
3402
SP202 FFC3
(PR)
3403
SP203 FFC4
(PR)
3404 SP204
3405 SP205
3406 SP206 GCK
8. Spindle Parameters
8.4 MDS-C1-SPM
Synchronized
Set the acceleration feed forward gain for
tapping
selection of gear 000 during synchronized
acceleration
tapping.
feed forward
This parameter should be used when an error
gain
of relative position to Z-axis servo is large.
(gear 1)
Synchronized
Set the acceleration feed forward gain for
tapping
selection of gear 001 during synchronized
acceleration
tapping.
feed forward
gain
(gear 2)
Synchronized
Set the acceleration feed forward gain for
tapping
selection of gear 010 during synchronized
acceleration
tapping.
feed forward
gain
(gear 3)
Synchronized
Set the acceleration feed forward gain for
tapping
selection of gear 011 during synchronized
acceleration
tapping.
feed forward
gain
(gear 4)
Fixed control
This is used by Mitsubishi.
constant
Set to "0" unless particularly designated.
Reverse run
When the motor moves (including movement
detection error
with external force), the motor overrun alarm
detection width
(3E) will be detected even if the speed
command is 0 (including position control stop
command) during servo ON (gate ON). Set
the movement amount to be detected as an
alarm.
0: Detect with 10° motor movement amount
(Recommended setting)
1: Detect with 20° motor movement amount
2: Detect with 40° motor movement amount
Details
II - 295
Setting
Standard
range
setting
0 to 1000
0
(%)
0 to 1000
0
(%)
0 to 1000
0
(%)
0 to 1000
0
(%)
0
0
0/1/2
0

Advertisement