Items
aux07
Synchronous
(bit2)
tap R-point
in-position
check
aux07
Synchronous
(bit3)
tap in-position
check
improvement
aux07
Synchronous
(bit4)
tap hole bottom
in-position
check
aux07
Synchronous
(bit5)
tap R-point
in-position
check 2
aux07
Cancel
(bit6)
synchronous
tap (,S) return
aux07
Synchronous
(bit7)
tap method
1224 aux08
Sampling data
(bit0)
output
5. Base Specifications Parameters
Details
0: Disable the synchronous tap I-point → R-point
in-position check.
1: Enable the synchronous tap I-point → R-point
in-position check.
(Applicable only to M64 D version series)
Note: This parameter is valid only when 1 (in-position
check is valid) is set in bit 3 of #1223 aux07
(synchronous tap in-position check
improvement).
Specify whether to enable the synchronous tap
in-position check improvement function. (Applicable
only to M64 D version series)
0: Disable
1: Enable
Related parameters:
#1223
bit 2 Synchronous tap R-point in-position check
bit 4 Synchronous tap hole bottom in-position
check
bit 5 Synchronous tap R-point in-position check 2
0: Disable the synchronous tap hole bottom
in-position check.
1: Enable the synchronous tap hole bottom
in-position check.
(Applicable only to M64 D version series)
Note: This parameter is valid only when 1 (in-position
check is valid) is set in bit 3 of #1223 aux07
(synchronous tap in-position check
improvement).
0: Disable synchronous tape R-point in-position
check.
1: Enable synchronous tape R-point in-position
check.
(Applicable only to M64 D version series)
Note: This parameter is valid only when 1 (in-position
check is valid) is set in bit 3 of #1223 aux07
(synchronous tap in-position check
improvement).
0: Retains a spindle rotation speed (, S) when
performing synchronous tap return.
1: Cancels a spindle rotation speed (, S) by return
with G80.
Specify a synchronous tap method.
0: Synchronous tap (multi-step acceleration and
deceleration and rapid return)
1: Conventional type synchronous tap
Set the validity of the sampling data output.
0: Sampling output invalid
1: Sampling output valid
II - 59
Setting range (unit)
0/1
0/1
0/1
0/1
0/1
0/1
0/1

Advertisement