No.
Items
3417 SP217 TINP
3418
SP218 TODR
(PR)
3419
SP219 IQGT
(PR)
3420
SP220 IDGT
(PR)
3421 SP221 PG2T
3422 SP222 PG3T
3423 SP223 SPDV
3424 SP224 SPDF
8. Spindle Parameters
8.4 MDS-C1-SPM
Synchronized
Set the position error range for output of
tapping
the in-position during synchronized
in-position
tapping.
width
Synchronized
Set the excessive error width during
tapping
synchronized tapping.
excessive error
width
Synchronized
Set the magnification of current loop gain
tapping current
(torque component) during synchronized
loop gain
tapping.
magnifi-
cation 1
Synchronized
Set the magnification of current loop gain
tapping current
(excitation component) during
loop gain
synchronized tapping.
magnifi-
cation 2
Synchronized
Set the second position loop gain when
tapping
high-gain control is applied during
position loop
synchronized tapping.
gain 2
When this parameter is not used, set to
"0".
Synchronized
Set the third position loop gain when
tapping
high-gain control is applied during
position loop
synchronized tapping.
gain 3
When this parameter is not used, set to
"0".
Speed monitor
Set the spindle limit speed in the door
speed
open state.
(Invalid when 0 is set.)
If the spindle end speed exceeds this
setting value when the door is open, the
speed monitor error (5E) will occur.
Speed monitor
Set the time (continuous) to detect alarms.
time
(Detected instantly when 0 is set.)
Details
II - 297
Setting
Standard
range
setting
1 to 2880
16
(1/16°)
1 to 32767
32767
(pulse)
(1 pulse
=0.088°)
1 to 1000
100
(%)
1 to 1000
100
(%)
0 to 999
0
(1/s)
0 to 999
0
(1/s)
0 to 800
0
(r/min)
0 to 2813
0
(3.5ms)

Advertisement