Note: Provide a separate external I/O power supply; the servo amplifier does not have an internal 24V
power supply.
External power supply specifications: 24V ±1 V
Yaskawa recommends using the same type of external power supply as that used for output circuits.
The function allocation for sequence input signal circuits can be changed.
See 5.3.3 Input Circuit Signal Allocation for more details.
ð Input +24VIN CN1-47
The external power supply input terminal is common to sequence input signals.
Contact input signals: /S-ON (CN1-40)
DC
External I/O Power Supply Input
I/O power supply
+ 24V
Connect an external I/O power supply.
/P-CON (CN1-41)
P-OT (CN1-42)
N-OT (CN1-43)
/ALM-RST (CN1-44)
/P-CL (CN1-45)
/N-CL (CN1-46)
5-26
Chapter 5: Parameter Settings and Functions
, 50mA minimum.
Speed/Torque Control,
Position Control
Servo Amplifier
+ 24VIN
CN1-47