5. Press the DATA/SHIFT key for less than one second to display the speed refer-
ence offset amount.
6. Press the Up Arrow
(adjustment of the speed reference offset).
7. Press the DATA/SHIFT key for less than one second to return to the display
shown in the above step 4.
8. Press the DATA/SHIFT key to return to the auxiliary function mode display.
This completes the speed reference offset manual adjustment.
or Down Arrow
key to adjust the amount of offset
7-32