Sigma II User's Manual
LED Number
1
2
3
4
5
6
7
Note: Refer to 5.3.4 Output Circuit Signal Allocation for details on output terminals.
Output signals are allocated as shown above and displayed on the panel of the servo
amplifier or the digital operator. They are indicated by the ON/OFF status of the
vertical parts of seven-segment displays located in top and bottom rows. (The hori-
zontal segments are not used here). These turn ON or OFF relative to the state of the
corresponding output signals (ON for "L" level and OFF for "H" level).
Example
When ALM signal operates (alarm at "H")
Output Signal Monitor Display
7 6 5
Output Terminal Name
(CN1-31, -32)
SO1 (CN1-25, -26)
SO2 (CN1-27, -28)
SO3 (CN1-29, -30)
(CN1-37)
(CN1-38)
(CN1-39)
7 6 5
7-20
Chapter 7: Using the Digital Operator
Top:
ON = High level
Bottom: ON = Low level
4 3 2 1 Number
Default Setting
ALM
/COIN or /V-CMP
/TGON
/S-RDY
AL01
AL02
AL03
Only the top segment
of number 1 is lit.
4 3 2 1 Number