T
Manual Gain Adjustment of Analog Monitor Output
Follow the procedure below to execute the manual gain adjustment of analog moni-
tor output.
Using the Hand–held Digital Operator
1. Press the DSPL/SET key to select the auxiliary function mode.
2. Select the parameter Fn00D.
Press the Left Arrow
Press the Up Arrow
3. Press the DATA/SHIFT key, and the display will be as shown below.
4. Press the DSPL/SET key. Each time the DSPL/SET key is pressed, the monitor
output will toggle between the displays for the two channels shown below.
5. Press the Left Arrow
gain parameter. Pressing the Left Arrow
return to the display shown above in step 3 or 4.
6. Press the Up Arrow
monitor output.
7. When the gain adjustment has been completed for the two channels, press the
DATA/ENTER key to return to the auxiliary function mode display.
This completes the manual gain adjustment of the analog monitor output.
or Right Arrow
key to select the digit.
or Down Arrow
key to change the value.
DSPL/SET Key
Displayed
Alternately
or Right Arrow
key to display the analog monitor
Left Cursor Key
(Right Cursor Key)
Data Display
Displayed
Alternately
or Down Arrow
key to adjust the gain for the analog
Data Setting Change
7-48
Chapter 7: Using the Digital Operator
or Right Arrow
key again will

Advertisement