2.2.1
Storage Conditions
Store the servo amplifier within the following temperature range, as long as it is
stored with the power cable disconnected.
-20 to 85°C
2.2.2
Installation Site
The following precautions apply to the installation site.
Situation
Installation in a Control
Panel
Installation Near a Heat-
ing Unit
Installation Near a
Source of Vibration
Installation at a Site
Exposed to Corrosive
Gas
Other Situations
YASKAWA
200V
SERVOPACK
SGDH-
MODE/SET
DATA/
POWER
CHARGE
L1
C
N
L2
3
L3
1
2
C
N
1
L1C
L2C
B1
B2
B3
C
U
N
2
V
W
Sigma II series servo amplifier
Installation Precaution
Design the control panel size, unit layout, and cooling
method so the temperature around the servo amplifier does
not exceed 55°C.
Minimize heat radiated from the heating unit as well as any
temperature rise caused by natural convection so the tem-
perature around the servo amplifier does not exceed 55°C.
Install a vibration isolator beneath the servo amplifier to
avoid subjecting it to vibration.
Corrosive gas does not have an immediate effect on
the servo amplifier, but will eventually cause elec-
tronic components and contactor–related devices to
malfunction. Take appropriate action to avoid corro-
sive gas.
Do not install the servo amplifier in hot and humid
locations or locations subject to excessive dust or iron
powder in the air.
2-6