Download Print this page

YASKAWA Sigma II Series User Manual page 332

Servo system

Advertisement

Sigma II User's Manual
n
CPF00
CPF00: Digital Operator Transmission Error 1
Display and Outputs
Status and Remedy for Alarm
Cable defective or poor contact
A
between digital operator and servo
amplifier.
B
Malfunction due to external noise.
C
Digital operator defective.
D
Servo amplifier defective.
This alarm is not stored in the alarm history.
Alarm Outputs
Alarm Code Output
ALO1
ALO2
Not Applicable
When the digital operator
is connected before or after
the servo amplifier has been
turned ON.
Cause of the Problem
Chapter 9: Inspection, Maintenance, and Troubleshooting
ALM Output
ALO3
A, B,
C, D
Solution
• Check connector connections.
• Replace cable.
Separate digital operator and cable
from noise source.
Replace digital operator.
Replace servo amplifier.
9-33