Download Print this page

YASKAWA Sigma II Series User Manual page 263

Servo system

Advertisement

Sigma II User's Manual
Using the Panel Operator
YASKAWA
200V
SERVOPACK
SGDM-
1. Press the MODE/SET key to select the auxiliary function mode.
MODE/SET
DATA/
CHARGE
POWER
2. Press the Up Arrow
3. Press the DATA/SHIFT key for a minimum of one second, and the display will
be as shown below.
4. Press the MODE/SET key. Each time the MODE/SET key is pressed, the mon-
itor output will toggle between the displays for the two channels shown below.
5. Press the DATA/SHIFT key for less than one second, and the analog monitor
gain parameter will be displayed. Pressing the DATA/SHIFT key again for less
than one second will return to the display shown in the above steps 3 or 4.
6. Press the Up Arrow
the analog monitor output.
7. When zero adjustment has been completed for the two channels, press the
DATA/SHIFT key for a minimum of one second to return to the auxiliary func-
tion mode display.
This completes the manual zero adjustment of the analog monitor output.
or Down Arrow
key to select the parameter Fn00C.
MODE/SET Key
Displayed
Alternately
Data Display
DATA/SHIFT Key
Displayed
Alternately
or Down Arrow
key to perform zero adjustment of
Data Setting Change