7.2.6
Checking the Motor Model
Set the parameter Fn011 to select the motor model check mode. This mode is used
for motor maintenance, and can also be used to check the special (Y-specification)
codes of the servo amplifiers.
Follow the procedure below to check the motor model.
Using the Hand-Held Digital Operator
1. Press the DSPL/SET key to select the auxiliary function mode.
2. Select the parameter Fn011.
Press the Left Arrow
Press the Up Arrow
3. Press the DATA/ENTER key to display the servomotor model and voltage code.
Voltage
Code
100V
00
200V
01
400V
02
4. Press the DSPL/SET key to display the Servomotor capacity.
or Right Arrow
or Down Arrow
Voltage
Servomotor Model
Voltage
Code
or 140V
AC
DC
or 280V
AC
DC
or 560V
AC
DC
7-37
Chapter 7: Using the Digital Operator
key to select the digit.
key to change the value.
Servomotor Mode
Servomotor Model
00
SGMAH
01
SGMPH
02
SGMSH
V
03
SGMGH-
A (1500rpm)
V
04
SGMGH-
B (1000rpm)
05
SGMDH
06
SGMUH
Capacity: Displayed value y 10 (W)
In this example, the capacity is 100 W