n
A.F1
A.F1: Power Line Open Phase
Display and Outputs
Status and Remedy for Alarm
When the main circuit's
power supply is turned ON.
One phase (L1, L2, or L3) of the main
A
circuit power supply is disconnected.
There is one phase where the line
B
voltage is low.
C
Servo amplifier defective.
Note: A and B tend to occur in a servo amplifier with a capacity of 500W or higher.
Alarm Outputs
Alarm Code Output
ALO1
ALO2
OFF
ON
Note:
OFF:
Output transistor is OFF (alarm state).
ON:
Output transistor is ON.
Cause of the Problem
Chapter 9: Inspection, Maintenance, and Troubleshooting
ALM Output
ALO3
OFF
OFF
When the control power
A, B
is turned ON.
Solution
• Check power supply.
• Check wiring of the main circuit
power supply.
• Check MCCB, noise filter, mag-
netic contactor.
Check power supply.
Replace servo amplifier.
9-32
C