3. Press the DATA/ENTER key, and the display will be as shown below. The man-
ual adjustment mode for the speed reference offset will be entered.
4. Turn ON the Servo ON (/S-ON) signal. The display will be as shown below.
5. Press the Left Arrow
offset amount.
6. Press the Up Arrow
(adjustment of the speed reference offset).
7. Press the Right Cursor Key to return to the display shown in the above step 4.
8. Press the DATA/ENTER key to return to the auxiliary function mode display.
This completes the speed reference offset manual adjustment.
Using the Panel Operator
YASKAWA
200V
SERVOPACK
SGDM-
1. Press the MODE/SET key to select the auxiliary function mode.
MODE/SET
DATA/
CHARGE
POWER
2. Press the Up Arrow
3. Press the DATA/SHIFT key for a minimum of one second, and the display will
be as shown below. The manual adjustment mode for the speed reference offset
will be entered.
4. Turn ON the Servo ON (/S-ON) signal. The display will be as shown below.
or Right Arrow
or Down Arrow
key to adjust the amount of offset
or Down Arrow
key to select the parameter Fn00A.
7-31
Chapter 7: Using the Digital Operator
key, to display the speed reference