Download Print this page

YASKAWA Sigma II Series User Manual page 168

Servo system

Advertisement

Sigma II User's Manual
This parameter sets the number of output pulses for PG output signals (PAO, /PAO,
PBO, /PBO).
Pulses from the motor encoder (PG) are divided by the number of pulses set here
before being output.
The set value is the number of output pulses per revolution. Set this value according
to the reference unit of the machine or controller to be used.
The setting range varies according to the encoder used.
Servomotor
Encoder
Setting Example
n
Transferring Alarm Contents
When an absolute encoder is used, SEN signals can be utilized to transfer the alarm
contents through PAO outputs to the host device as serial data.
SEN Signal
Digital Operator Display
PAO Serial Data
Note: Refer to 9.2.3 Alarm Display Table for a table of alarm contents.
Servo amplifier
PS
PAO
PG
Divider
PBO
Set value: 16
Motor one revolution
Alarm Contents Output Example
or
Incremental pulses
Chapter 5: Parameter Settings and Functions
Output terminals:
PAO (CN1-33)
Output
/PAO (CN1-34)
PBO (CN1-35)
/PBO (CN1-36)
High: Error detection
Absolute encoder
backup alarm
5-101
Low
ALM81
CR

Advertisement