YASKAWA Sigma II Series User Manual page 225

Servo system

Advertisement

Sigma II User's Manual
5. Press the DATA/ENTER key to store the data. The display will flash.
6. Press the DATA/ENTER key again to return to the parameter number display.
This procedure has changed the setting of the parameter Pn507 from 100 to 85.
Repeat steps 2 to 6 to change the setting again.
Example Using the Panel Operator
YASKAWA
200V
SERVOPACK
SGDM-
1. Press the MODE/SET key to select the parameter setting mode.
MODE/SET
DATA/
CHARGE
POWER
2. Press the Up Arrow
to set. (Pn507 is selected in this example.)
3. Press the DATA/SHIFT key for a minimum of one second to display the current
data for the parameter selected in step 2.
4. Press the the Up Arrow
value of "00085".
As you keep pressing the Up Arrow
changes faster.
5. Press the DATA/SHIFT key for a minimum of one second to save the data. The
display will flash.
6. Press the DATA/SHIFT key once more for a minimum of one second to display
the parameter number again.
This has changed the setting of the parameter Pn507 from 100 to 85.
or Down Arrow
key to select the parameter number
or Down Arrow
or Down Arrow
7-9
Chapter 7: Using the Digital Operator
key to change to the desired
key, and the display