Application Example: Equipment Protection
Motor
speed
Using the /CLT Signal
The following section describes the use of the contact output signal /CLT as a torque
limit output signal.
Photocoupler output
Maximum operating voltage
per output: 30VDC
Maximum operating current
per output: 50mADC
Output ð /CLT CN1-*1
This signal indicates whether servomotor output torque (current) is being limited.
Status
The circuit between CN1–*1 and *2
is closed.
ON
CN1–*1 is at low level.
The circuit between CN1–*1 and *2
is open.
OFF
CN1–*1 is at high level.
Settings:
When the /CLT signal is used, the following parameter must be used to select the
output signal.
Parameter
Pn50F
Output Signal Selections 2
Torque limit
Too small a torque limit will result in a
insufficient torque during acceleration and
deceleration.
Torque
Torque Limit Output
Conditions
Pn402 (Forward Torque Limit)
Pn403 (Reverse Torque Limit)
Pn404 (Forward External Torque Limit): /P-CL input only
Pn405 (Reverse External Torque Limit): /N-CL input only
Signal
Chapter 5: Parameter Settings and Functions
Servo Amplifier
CN1-*1
CLT+
CN1-*2
CLT-
Speed/Torque Control,
Position Control
Description
Servomotor output torque is being limited.
(Internal torque reference is greater than
the limit setting).
Servomotor output torque is not being lim-
ited.
(Internal torque reference is less than the
limit setting).
Setting
Default Setting: 0000
5-10
I/O power supply
+ 24V
Control Mode
Speed/Torque Control,
Position Control