6.13.4 Display
Standardization
6.12.4 Definition of own standardization
Standard
Inverted
ud.18 Display standardization
Divisor
ud.19 Display standardization
Multiplier
ud.20 Display standardization
ud.21 Display standardization
Chapter
Section
Page
6
13
6
The KEB COMBIVERT gives the user the possibility to define his own standardization
(e.g. km/h or bottles/min) in the CP-Mode. The parameters ud.18...20 are used for
conversion, ud.21 for specifying the method of calculation, the decimal places as well
as the units indicated in KEB COMBIVIS.
ud.19 Multiplier
± 32767
CP.xx = (selected parameter + ud.20) x
ud.20 Offset
± 32767
ud.19 Multiplier
± 32767
CP.xx =
ud.20 Offset
± 32767
The unstandardized value is always used for the „selected parameter" !
Adjusts the divisor in the range of ±32767 (default 1). The parameter is set-
programmable (not at B-control).
Adjusts the multiplier in the range of ±32767 (default 1). The parameter is set-
programmable (not at B-control).
Adjusts the offset in the range of ±32767 (default 0). The parameter is set-programmable
Offset
(not at B-control).
With ud.21 the calculation mode, the decimal places as well as the units indicated in
Mode
KEB COMBIVIS are adjusted. The parameter is bit-coded and set-programmable (not
at B-control). It is adjustable in the range of 0...4095.
Bit 12...15
-
-
-
free
Date
Name: Basis
04.05.04
KEB COMBIVERT F5
ud.19
(selected parameter + ud.20) x ud.18
Bit 11...8
Bit 7...6
-
-
-
see table 2
see table 3
-
-
-
CP-Parameter Definition
ud.19
x Unit
ud.18
ud.18 Divisor
± 32767
ud.21 Display flags
0...4095
x Unit
ud.18 Divisor
± 32767
Bit 5...0
ud.21
see table 1
Unit
-
Calculation mode
-
Representation
-
-
©
KEB Antriebstechnik, 2002
All rights reserved