KEB COMBIVERT F5 MULTI Applications Manual page 110

Hide thumbs Also See for COMBIVERT F5 MULTI:
Table of Contents

Advertisement

Functional Desription
ru.80 digital output state
Adr.
0250h
With do.51 the digital output signals can be assigned to the hardware outputs (see chapter 6.3). This parameter displays
the status of the output signals before the assignment according to following table. If several outputs are set, the total
sum of their decimal values is indicated.
Bit -No.
0
1
2
3
4
5
6
7
ru.81
active power
Adr.
0251h
ru.81 displays the current active power of the inverter. In regenerative operation the negative values are displayed.
Chapter
Section
Page
6
1
20
min
max
0
255
Decimal value
Output
1
O1 (Transistor output 1)
2
O2 (Transistor output 2)
4
R1 (Relay RLA,RLB,RLC)
8
R2 (Relay FLA,FLB,FLC)
16
OA (Internal output A)
32
OB (Internal output B)
64
OC (Internal output C)
128
OD (Internal output D)
min
max
-400,00
400,00
Date
Name: Basis
KEB COMBIVERT F5-M / S
12.05.04
Operating and Unit Data
-
1
Terminal
X2A.18
X2A.19
X2A.24...26
X2A.27...29
keine
keine
keine
keine
kW
0,01
0,01
©
KEB Antriebstechnik, 2002
All Rights reserved
default
-
default

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Combivert f5 servo

Table of Contents