Functional Desription
ru.13
Actual utilization
Adr.
020Dh
Display of the current utilization referred to the rated current of the inverter. Only positive values are indicated, thus it is
not possible to differentiate between a motoric or generatoric operation.
ru.14
Peak utilization
Adr.
020Eh
ru.14 allows the detection of short-time peak utilizations during an operating cycle. For that the highest detected value
of ru.13 is stored in ru.14. The peak value memory is cleared by pressing the keys UP, DOWN or ENTER or by bus by
writing any chosen value to the address of ru.14. The disconnection of the inverter also results in a clearing of the
memory.
ru.15
Apparent current
Adr.
020Fh
Display of actual apparent curent.
ru.16
Peak apparent current
Adr.
0210h
ru.16 allows the detection of short-time peak currents during an operating cycle. For that the highest detected value of
ru.15 is stored in ru.16. The peak value memory is cleared by pressing the keys UP, DOWN or ENTER or by bus by
writing any chosen value to the address of ru.16. The disconnection of the inverter also results in a clearing of the
memory.
Chapter
Section
Page
6
1
8
min
max
0
65535
min
max
0
65535
min
max
0
6553,5
min
max
0
6553,5
Date
Name: Basis
KEB COMBIVERT F5-M / S
12.05.04
Operating and Unit Data
%
1
%
1
A
0,1
A
0,1
©
KEB Antriebstechnik, 2002
All Rights reserved
default
-
default
-
default
-
default
-