6.1.7 Description of Sy (System) - Parameter

Sy. 2
Inverter identifier
Adr.
0002h
A unique number is assigned to each type of frequency inverter which identifies the hard- and software. This value is
used for example by COMBIVIS to load the correct configuration files. Sy.2 kann mit dem angezeigten Wert beschrieben
werden (z.B. zur Identifikation von Downloadlisten).
Sy. 3
Power unit code
Adr.
0003h
On the basis of the power circuit identification the control recognizes the used power circuit respectively a change of the
power circuit and adjusts certain parameters accordingly. To accept a new P-Id enter positive values (see chap. 9
ÑE.Puchì).
Sy. 6
Inverter address
Adr.
0006h
With Sy.6 the address is adjusted under which the inverter is addressed by ÑCOMBIVISì or another control. The possible
values are between 0 and 239, the default value is 1. If several inverters are operated simulaneously on the bus, it is
absolutely necessary to assign different addresses, since otherwise communication problems arise because several
inverters may responded at the same time. The development info DIN 66019II protocol (C0.F5.01I-K001) contains
further information.
Sy. 7
Baud rate ext. bus
Adr.
0007h
Following values are possible for the baudrate of the serial interface:
Parameter value
0
1
2
3 (default)
4
5
6
If the value for the baudrate is changed over the serial interface, it can only be changed again by way of the keyboard
or after adapting the baudrate of the master, since no communication is possible in the case of different baudrates
between master and slave.
If problems occur during the data transmission, select a baudrate up to max. 38400 baud.
©
KEB Antriebstechnik, 2002
All Rights reserved
min
max
0000
9999
min
max
-255
255
min
max
0
239
min
max
0
6
Baudrate
1200 baud
2400 baud
4800 baud
9600 baud
19200 baud
38400 baud
55500 baud
Name: Basis
KEB COMBIVERT F5-M / S
Functional Desription
hex
1
P-ID
1
-
1
-
1
Date
12.05.04
default
-
default
-
default
1
default
5
Chapter
Section
Page
6
1
25
6

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Combivert f5 servo

Table of Contents