Keyboard And Display - KEB COMBIVERT G6 series Installation Manual

Housing c power 5.5...11kw
Hide thumbs Also See for COMBIVERT G6 series:
Table of Contents

Advertisement

Control
4.1.2

Keyboard and display

The operation of the unit via keyboard and display is described in the manual „PLF501B-
K001.PDF".
4.1.3
Diagnosis/visualisation
The integrated RS232/485 interface serves for the connection of service tools (e.g. COM-
BIVIS) and display. Telegram DIN66019II is used as communication protocol.
Interface
RS485
RS232
RS232/USB
4.1.3.1 Assignment of the interface X4A
GB - 24
LCD display, 160 x 160 pixel, 32 levels of grey
The LCD display offers a clear display of the information
with plain text display.
Function strip
The function strip displays the actual possible functions
of the keys F1 to F4. A flashing function strip indicates an
inverter error.
Function keys F1 to F4
The function keys F1 to F4 are variable assigned. The
assignment is displayed by the function key.
Up and Down
With "▲" and "▼" you can move between the menu items
or change parameter values.
ESC
With ESC you reach the upper level menu.
Enter
With ENTER you reach the selected menu item or a se-
lection can be confirmed.
Standard
TIA/EIA-485 and ISO 8482
ANSI TIA/EIA-232
reserved
1
TxD (RS232)
2
RxD (RS232)
3
RxD-A (RS485)
4
RxD-B (RS485)
5
Connecting cable
0058025-001D
0058060-0020
6
reserved
7
DGND (reference potential)
8
TxD-A (RS485)
9
TxD-B (RS485)