KEB COMBIVERT F5 MULTI Applications Manual page 19

Hide thumbs Also See for COMBIVERT F5 MULTI:
Table of Contents

Advertisement

Product Description
2.1.4
Type Code
10.F5.G1Bñ3200
1) GTR 7: brake transistor
2) PFC:
Power Factor Control
©
KEB Antriebstechnik, 2002
All Rights reserved
at FI: Cooling
0: Standard
1: Flat rear
2: Water-cooled
3: Convection
Encoder interface type see control part
0: no interface
5: Resolver a. SSI
1: Ink.-Input a. Ink.-I/O 6: Hiperface a. SSI
2: Resolver a. Ink.-I/O 7: Ink.-Input a. Tacho
3: Hiperface a. Ink.-I/O 8: Resolver a. Tacho
4: Ink.-Input a. SSI
9: Hiperface a. Tacho
at FI: Switching frequency / max. short time current / OC-tripping current
0: 2 kHz/125%/150%
5: 4 kHz/150%/180%
1: 4 kHz/125%/150%
6: 8 kHz/150%/180%
2: 8 kHz/125%/150%
7: 16 kHz/150%/180%
3: 16 kHz/125%/150%
8: 2 kHz/180%/216%
4: 2 kHz/150%/180%
9: 4 kHz/180%/216%
at Servos: motor speed
1: 1500 rpm
2: 2000 rpm
Input identification
0:
1ph 230V AC/DC
1:
3ph 230V AC/DC
2:
1/3ph 230V AC/DC
3:
3ph 400V AC/DC
4:
230V DC
Housing type
Accessory
0: without
1: GTR 7
1)
2: integrated filter
3: GTR 7
, integrated filter
1)
Control type
B: BASIC (controlled frequency inverter with standard function)
G: GENERAL (controlled frequency inverter with enhanced function)
C: COMPACT (controlled frequency inverter with enhanced function)
M: MULTI (regulated, field-oriented frequency inverter for three-phase asynchronous motors)
S: SERVO (regulated frequency inverter for synchronous motors)
Series
at FI in the 1. and 2. place: unit size
at Servos: motor identification / motor dimension wide
Name: Basis
KEB COMBIVERT F5
at Servos: motor cooling
0: Self-cooling
1: External cooling
A: Ink.-Input a. Initiator F: Hiperface a. Ink.-Outp.
B: Resolver a. Initiator
C: Hiperface a. Initiator H: Resolver a. Ink.-Inp.
D: Ink.-Input a. Ink.-Outp. I: Hiperface a. Ink.-Inp.
E: Resolver a. Ink.-Outp.
A:
8 kHz/180%/216%
B: 16 kHz/180%/216%
C: 2 kHz/200%/240%
D: 4 kHz/200%/240%
E:
8 kHz/200%/240%
3: 3000 rpm
4: 4000 rpm
5:
400V DC
6:
1ph 230V AC
7:
3ph 230V AC
8:
1/3ph 230V AC
9:
3ph 400V AC
A, B, D, E, G, H, R, U, W
4: integrated PFC
5: GTR 7
, integrated PFC
1)
6: integrated filter , integrated PFC
7: GTR 7
, integrated filter, integrated PFC
1)
F5
Summary
G: Ink.-Input a. Ink.-Inp.
F: 16 kHz/200%/240%
G: 2 kHz/400%/480%
H: 4 kHz/400%/480%
I:
8 kHz/400%/480%
K: 16 kHz/400%/480%
6: 6000 rpm
A:
6ph 400V AC
Z:
230V AC or AC/DC
Y:
400V AC or AC/DC
W:
230V DC
V:
400V DC
2)
2)
2)
Date
Chapter
Section
1
2
04.05.04
2
2)
Page
5
5

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Combivert f5 servo

Table of Contents