Operation
Deceleration time forward
Chapter
Section
Page
4
3
16
Defines the time needed to decelerate from 1000 to 0 rpm. The actual deceleration
time is proportional to the speed change (∆ n). At a deceleration time of -0,01 the
value from CP.25 is used (Display: Ñ=Accì)!
Adjustment range:
Resolution:
Factory setting:
n [rpm]
∆ t
1000
800
∆ n
300
0
0,5
1
CP.26
Example:
The drive should decelerate from 800 rpm to 300 rpm in 1 s.
∆ ∆ ∆ ∆ ∆ n
= 800 rpm - 300 rpm = 500 rpm
∆ ∆ ∆ ∆ ∆ t
= 1 s
∆ t
CP.26 =
ññññ x 1000 rpm
∆ n
Date
Name: Basis
17.05.04
KEB COMBIVERT F5-M / S
-1; 0,00...300,00 s
∆ n
∆ t
t [s]
1,5
2
1 s
=
ññññññññ
500 rpm
CP - Parameter
0,01 s
5,00 s
speed change
deceleration for ∆ n
x 1000 rpm = 2 s
©