KEB COMBIVERT F5 MULTI Applications Manual page 65

Hide thumbs Also See for COMBIVERT F5 MULTI:
Table of Contents

Advertisement

CP - Parameter
KP speed
KI speed
Switching frequency
©
KEB Antriebstechnik, 2003
All Rights reserved
The proportional factor of the speed controller is adjusted in these parameters (see
chapter 7.2 ÑStart-upì).
Adjustment range:
Resolution:
Factory setting:
The integral factor of the speed controller is adjusted in these parameters (see chapter
7.2 ÑStart-upì).
Adjustment range:
Resolution:
Factory setting:
The switching frequency with which the power modules are clocked can be changed
depending on the application. The employed power stage determines the maximum
switching frequency as well as the factory setting (see manual: part2). Refer to following
list to learn about influences and effects of the switching frequency.
low switching frequency
Åless inverter heating
Åless discharge current
Åless switching losses
Åless radio interferences
Åimproved concentricity with low speed
(only controlled!)
Adjustment range (dep. on power circuit): 2 / 4 / 8 / 12 / 16 kHz
Factory setting:
Note:
At switching frequencies above 4 kHz pay absolute attention to the max.
motor line length in the technical data of the chapter 2.1.
Name: Basis
KEB COMBIVERT F5-M / S
Operation
0...32767
1
300
0...32767
1
100
high switching frequency
Åless noise development
Åimproved sine-wave simulation
Åless motor losses
Åimproved controller characteristics
depending on power circuit
ENTER-Parameter
Date
Chapter
Section
4
17.05.04
4
Page
3
19