KEB COMBIVERT F5 MULTI Applications Manual page 99

Hide thumbs Also See for COMBIVERT F5 MULTI:
Table of Contents

Advertisement

Operating and Unit Data
ru.17
Active current
Adr.
0211h
Display of the torque-forming active current (stator losses already deducted). Negative current corresponds to generatoric
operation, positive current corresponds to motoric operation. The more precise the input of the motor data , the more
precise the indication of the active current. The maximum values depend on the size of the inverter.
ru.18
Actual DC voltage
Adr.
0212h
Display of actual DC-link voltage in volt. Typical values:
Normal operation: 230V-class 300-330V
400V-class 530-620V
ru.19
Peak DC voltage
Adr.
0213h
ru.19 allows the detection of short-time peak DC voltage during an operating cycle. For that the highest detected value
of ru.18 is stored in ru.19. The peak value memory is cleared by pressing the keys UP, DOWN or ENTER or by bus by
writing any chosen value to the address of ru.19. The disconnection of the inverter also results in a clearing of the
memory.
ru.20
Output voltage
Adr.
0214h
Display of actual output voltage.
©
KEB Antriebstechnik, 2002
All Rights reserved
min
max
- 3276,7
3276,7
min
max
0
1000
over volt. (E.OP): approx. 400V
min
max
0
1000
min
max
0
778
Name: Basis
KEB COMBIVERT F5-M / S
Functional Desription
A
0,1
V
1
under volt. (E.UP): approx. 216V
approx. 800V
V
1
V
1
Date
12.05.04
default
-
default
-
approx. 240V
default
-
default
-
Chapter
Section
Page
6
1
9
6

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Combivert f5 servo

Table of Contents