Operation
Torque reference source
Torque limit
Chapter
Section
Page
4
3
18
With this parameter the required setpoint source for torque control can be adjusted.
Value
Meaning
0
AN1+ / AN1-
1
AN2+ / AN2-
2
digital absolute (CP.29)
3
only application mode
Adjustment range:
Resolution:
Factory setting:
Note:
The absolute torque reference of the drive is adjusted with parameter CP.29 in torque-
controlled operation (CP.10 = 5) and with digital setpoint setting (CP.28 = 2). The sign
stands for direction of rotation to be active.
In speed-controlled operation (CP.10†=†4) the parameter works as torque limit in all
quadrants.The sign has no effect at that.
The factory setting depends on the unit size (see 3.7 ÑFactory Settingsì).
Adjustment range:
Resolution:
Factory setting:
F5-MULTI:
During controlled operation (CP.10 = 0...3) this parameter has no function.
Because of normal type differences and temperature deviations of the motors,
tolerances of up to 30% are possible in the base speed range (see reference on page
4.3.5).
Date
Name: Basis
17.05.04
KEB COMBIVERT F5-M / S
CP - Parameter
0%...±100% = 0...±CP.29
0%...±100% = 0...±CP.29
0...5
1
2
Enter-Parameter
+10000,00 Nm
0,01 Nm
LTK
©
KEB Antriebstechnik, 2003
All Rights reserved
CP .29