Digital In- and Outputs
Edge-active or static Strobe?
di.7 Strobe-mode
©
KEB Antriebstechnik, 2002
All rights reserved
As a standard the Strobe is edge-active, i.e. the input conditions on the Strobe input
are accepted with rising edge and maintained until the next edge. For some applications
it is sensible to use the Strobe in a manner of a gate function. In that case the Strobe
signal is static, i.e. the input signals are accepted for as long as the Strobe signal is
set (or for as long as the gate is open).
Parameter
Setting range
di.7
0
1
2
Fig. 6.3.8.a Edge-active Strobe (di.7=0)
1ms
Scanning grid
(acceptance upon
rising edge)
Strobe input
Resulting
Strobe signal
Signal at
terminals
Input status
Fig. 6.3.8.b Static Strobe Mode 1 (di.7=1)
Signal at
terminals
Strobe input
Input status
Fig. 6.3.8.c Static Strobe Mode 2 (di.7=2)
Signal at
terminals
Strobe input
Input status
Name: Basis
KEB COMBIVERT F5
Functional Description
Function
edge-active Strobe (default)
static strobe - frooze if strobe is not active
static strobe - only active at active strobe
Date
28.01.03
t
t
t
t
t
t
t
t
t
t
t
Chapter
Section
Page
7