Product Description
Inverter Size
Housing size
Phases
Output nominal power
Max. rated motor power
Output nominal current
1)
Max. short time current
OC-tripping current
Nominal input current
Max. permissible mains fuse (inert)
Rated switching frequency
Max. switching frequency
Power loss at nominal operating
2)
Stall current at 4kHz
2)
Stall current at 8kHz
2)
Stall current at 16kHz
Max. heat sink temperature TOH
3)
Motor line cross section
4)
Min. braking resistor
4)
Typ. braking resistor
Max. braking current
Overload curve (page appendex)
Tightening torque for terminals
5)
Mains voltage
Mains frequency
Output voltage
Output frequency
Max.shielded motor line length
Storage temperature
Operating temperature
Model / protective system
Relative humidity
EMC tested according to
Climatic category
1) With the regulated systems F5-M as well as F5-S 5% are to be subtracted as control reserve.
2) Fuses of type Ferraz Shawmut 6,6 UD Type 31
3) Max. current before the responding of the OL2-function (only F5-M; F5-S; F5-A)
4) Recommended minimum cross section for rated power and a cable length of upto 100m (copper)
5) This data is only valid for units with internal brake transistor (see "unit identification")
6) Rated voltage 400V; at mains voltage ≥ 460V multiply the rated current with factor 0.86.
7) The temperature range is only valid for the control circuit. For the power circuit the temperature range is depending on
the control cabinet installation and the cooling system.
8) 31.F5 only watercooled.
©
KEB Antriebstechnik, 2002
All Rights reserved
14
E
G
3
[kVA]
13
[kW]
7,5
[A]
33
[A]
49,5
[A]
59
[A]
43
[A]
50
[kHz]
4
16
[kHz]
16
[W] 350
410
[A]
33
36
[A]
24
33
[A] 16,8
26
[∞ C]
[mm≤ ]
10
[Ohm]
16
8
[Ohm]
20
[A]
25
50
[Nm]
1,2
2,5
[V]
[Hz]
[V]
[Hz]
[m]
[∞ C]
[∞ C]
Name: Basis
KEB COMBIVERT F5
Summary
15
16
17
G
H
H
R
3
3
3
19
26
33
11
15
18,5
48
66
84
72
99
126
86
119
151
63
86
92
80
80
100
8
16
16
8
16
16
16
16
460
430
550
850
36
53
72,5
92
-
53
72,5
84
-
53
66
50
90
25
25
35
8
5,6
5,6
4,7
13
10
7
50
70
70
85
1
4
180...260 ±0 (230 V Nominal voltage)
50 / 60 +/- 2
3 x 0...U Mains
see Control board
100
-25...70 ∞ C
-10...45 ∞ C
IP20
max. 95% without condensation
EN 61800-3
3K3 in accordance with EN 50178
Date
04.05.04
18
19
20
21
R
R
R
R
3
3
3
3
40
46
59
71
22
30
37
45
100
115
145
180
150
172
217
270
180
206
261
324
116
126
165
198
160
160
200
315
8
8
8
8
8
8
8
8
1020 1200 1350 1620
110
126
159
198
100
115
145
180
-
-
-
-
50
50
95
95
4,7
3,9
2
2
5,6
4,7
3,9
3,0
85
102
160
160
6
50
Chapter
Section
Page
7
1
7
2
2

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Combivert f5 servo