Basic Setting - KEB COMBIVERT F5 MULTI Applications Manual

Hide thumbs Also See for COMBIVERT F5 MULTI:
Table of Contents

Advertisement

Functional Description

6.10.6 Basic Setting

Encoder interface 1 / 2
(Ec.0, Ec.10)
Adjustment of encoder line
number (Ec.1, Ec.11)
Speed sampling time
(Ec.3, Ec.13)
Chapter
Section
Page
6
10
10
Prior to start-up the inverter must be adapted to the encoder(s) which is/are used.
Ec.0 displays the installed encoder interface 1; Ec.10 displays the installed encoder
interface 2. The values correspond to following interfaces:
Value Encoder interface
0
no Interface
1
Incremental encoder input TTL
2
Incremental encoder output 5 V
3
Incremental encoder input and output direct (not divisible by Ec.27;
switchable with Ec.20)
4
Incremental encoder input and output TTL (switchable with Ec.20)
5
Initiator
6
SSI Interface
7
Resolver Interface
8
Tacho
9
Incremental encoder output TTL (from resolver over channel 2)
10
Incremental encoder output TTL
11
Hiperface
12
Incremental encoder input 24 V HTL
13
Incremental encoder input TTL with error detection
14
Sin/cos encoder input
15
Incremental encoder input 24 V HTL with error detection (push-pull)
16
ENDAT
17
Incremental encoder input 24 V HTL with error detection
18
Analog option ±10 V
In case of an invalid encoder indentification the error ÑE.Hybì is indicated and the
measured value in is displayed inverted in ec.0/ec.10.
On changing the encoder interface the error ÑE.HybCì is indicated. By writing on
parameter ec.0 or ec.10 the change is confirmed and the default values for the new
interface are loaded.
With this parameter the encoder line number is adjusted to the connected encoder
within a range of 1Ö16383.
ï
ec.1 for encoder interface 1
ï
ec.11 for encoder interface 2
This parameter defines the time over which the speed average is determined. At that
the resolution of the speed detection is defined simultaneously.
ec.3 Sampling
ec.13
time
0
0,5 ms
1
1 ms
2
2 ms
3
4 ms
4
8 ms
5
16 ms
6
32 ms
7
64 ms
8
128 ms
9
256 ms
Date
Name: Basis
17.02.03
KEB COMBIVERT F5
Speed resolution with the use of an
incremental encoder with 2500 pulses
12 rpm
6 rpm
3 rpm
1,5 rpm
0,75 rpm
0,375 rpm
0,1875 rpm
0,09375 rpm
0,046875 rpm
0,0234375 rpm
©
Encoder Interface
(Factory setting)
KEB Antriebstechnik, 2002
All rights reserved

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Combivert f5 servo