KEB COMBIVERT F5 MULTI Applications Manual page 66

Hide thumbs Also See for COMBIVERT F5 MULTI:
Table of Contents

Advertisement

Operation
Relay output 1 / Function
Relay output 2 / Function
Chapter
Section
Page
4
3
20
CP.33 and CP.34 determine the function of the two outputs.
(terminal X2A.24...X2A.26 and X2A.27...X2A.29)
Value
Function
0
No function (generelly off)
1
Generelly on
2
Run signal; also by DC-braking
3
Ready signal (no error)
4
Fault relay
5
Fault relay (not at under voltage error)
6
Warning or error message at abnormal stopping
7
Overload alert signal
8
Overtemperature alert signal power modules
9
External Overtemperature alert signal motor
10
Only application-mode
11
Overtemperature alert signal interior OHI
12-19
Only application-mode
20
Actual value = set value (CP.3 = Fcon, rcon; not at noP, LS error, SSF)
21
Accelerate (CP.3 = FAcc, rAcc, LAS)
22
Decelerate (CP.3 = FdEc, rdEc, LdS)
23
Real direction of rotation = set direction of rotation
24
Utilization > switching level
25
Active current > switching level
26
Only application-mode
27
Real value (CP.1) > switching level
28
Set value (CP.2) > switching level
29-30
Only application-mode
31
Absolut set value on AN1 > switching level
32
Absolut set value on AN2 > switching level
33
Only application-mode
34
Set value on AN1 > switching level
35
Set value on AN2 > switching level
36-39
Only application-mode
40
Hardware current limit activated
41
Modulation on-signal
42-46
Only application-mode
47
Ramp output value > switching level
48
Apparent current (CP.4) > switching level
49
Forward running (not at nOP, LS, abnormal stopping or error)
50
Reverse running (not at nOP, LS, abnormal stopping or error)
51
Warning E.OL2
52
Current regulator limit reached
53
Speed regulator limit reached
54-62
Only application-mode
63
Absolut value ANOUT1 > switching level
64
Absolut value ANOUT2 > switching level
65
ANOUT1 > switching level
66
ANOUT2 > switching level
67-69
Only application-mode
70
Driver voltage active (safety-relay)
71-72
Only application-mode
73
74
75
Only application-mode
1)
Switching level of CP.33 = 100; Switching level of CP.34 = 4
Date
Name: Basis
17.05.04
KEB COMBIVERT F5-M / S
CP - Parameter
1)
1)
1)
1)
1)
1)
1)
1)
1)
1)
1)
1)
1)
1)
©
KEB Antriebstechnik, 2003
All Rights reserved

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Combivert f5 servo

Table of Contents