Positioning and Synchronous Control
6.11.6 Reference Point
Approach -
Examples
Pic. 6.11.6.a
Reference point approach example 1
Limit switch left +
Reference switch
Position after reference point approach
(independent from PS.14 Bit 3)
Start ref.-approach
V
1
Signal at X2A.15
0
©
KEB Antriebstechnik, 2002
All Rights reserved
One limit switch serves at the same time as reference point switch.
Terminal X2A.14 = limit switch right (di.19 = 32)
Terminal X2A.15 = limit switch left + reference point switch (di.20 = 67108920)
Terminal X2A.10 = start reference point approach (di.11 = 134217728)
Reference speed = -100 rpm with counter-clockwise rotation (PS.21 = -100)
V
= -100 rpm
Ref
Starting position
Name: Basis
KEB COMBIVERT F5-M / S
Functional Desription
Limit switch right
clear the reference limit
switch with
0.25* PS.21
turn back
of zero encoder
Date
06.05.04
t
t
Chapter
Section
Page
6
11
9
6
Need help?