Functional Description
6.12.5 Used Parameters
Parameter
cn 0 PID reference source
cn 1 PID abs. reference
cn 2 PID act. value source
cn 3 PID abs. act. value
cn 4 PID kp
cn 5 PID ki
cn 6 PID kd
cn 7 PID pos. limit
cn 8 PID neg. limit
cn 9 PID fading time
cn10 PID reset condition
cn11 PID reset inp. sel.
cn12 I reset inp. sel.
cn13 fade in reset inp. sel.
cn14 PID out freq at 100%
ru13 Actual utilization
ru17 Active current
ru18 Actual DC voltage
ru28 AN1 post amplifier display
ru30 AN2 post amplifier display
ru53 AUX display
Chapter
Section
Page
6
12
10
Addr.
0700 X
X
–
0701 X
X
–
0702 X
X
–
0703 X
–
–
0704 X
X
–
0705 X
X
–
0706 X
X
–
0707 X
X
–
0708 X
X
–
0709 X
X
–
070A X
X
–
070B X
–
X
070C X
–
X
070D X
–
X
070E X
X
–
020D –
–
–
0211
–
–
–
-3276,7
0212
–
–
–
021C –
–
–
021E –
–
–
0235
–
–
–
Date
Name: Basis
04.05.04
KEB COMBIVERT F5
max
min
0
4
1
-400,0
400,0
0,1
0
7
1
-400,0
400,0
0,1
0,00
250,00
0,01
0,000
30,000
0,001
0,00
250,00
0,01
-400,0
400,0
0,1
-400,0
400,0
0,1
-0,01
300,00
0,01
0
2
1
0
4095
1
0
4095
1
0
4095
1
-400,0
400,0
0,0125
0
255
1
3276,7
0,1
0
1000
1
-400,0
400,0
0,1
-400,0
400,0
0,1
-400,0
400,0
0,1
Technology Control
[?]
Notes
default
0
–
–
0,0
%
–
0
–
–
0,0
%
–
0,00
–
–
0,000
–
–
0,00
–
–
400,0
%
–
-400,0
%
–
0,00
s
-0,01 freq. dependend
0
–
–
0
–
–
0
–
–
0
–
–
0
Hz
dependend on ud.2
0
%
–
0
A
–
0
V
–
0
%
–
0
%
–
0
%
–
©
KEB Antriebstechnik, 2002
All rights reserved