Copying Of Parameter Sets Via Keyboard (Fr.1); Copying Of Parameter Sets Via Bus (Fr.1, Fr.9); Parameters; Security-Parameters - KEB COMBIVERT F5 MULTI Applications Manual

Hide thumbs Also See for COMBIVERT F5 MULTI:
Table of Contents

Advertisement

Functional Description
6.8.5
Copying of Para-
meter Sets via
Keyboard (Fr.1)
6.8.6
Copying of Para-
meter Sets via
Bus (Fr.1, Fr.9)
By loading the factory setting
all definitions defined by the
mechanical engineer are
reset! This can comprise the
terminal
assignment,
changeover or operating states.
Before loading the default set it
is to be ensured that no
unintended operating states
occur.
Chapter
Section
Page
6
8
4
Adjust target set
A Fr
1
·
0 Fr
1
·
1 Fr
1
·
DOWN
2 Fr
1
·
3 Fr
1
·
4 Fr
1
·
UP
5 Fr
1
·
6 Fr
1
·
7 Fr
1
·
With the keys UP/DOWN and at
flashing point the target set is adju-
sted in addition to the parameter set
number. The active (A) parameter set
must not be adjusted as target set
while copying. If the target set is > 0,
only the programmable parameters
are overwritten!
In the case of indirect set addressing at Bus operation two parameters are responsible
for the copying of parameter sets. Fr.9 defines the target set. Fr.1 defines the source
parameter set and starts the copying process. Parameter Fr.9 is not visible via
keyboard. In the case of direct set programming the source set (Fr.1) is copied into
the selected parameter sets. The following copying actions can be practised:
Target Set Source Set Action
0...7
0...7
0
-1: dEF_S
set
1...7
-1: dEF_S
all
-2: dEF_A
0
-3: ini_S
1...7
-3: ini_S
all
-4: ini_A
Date
Name: Basis
KEB COMBIVERT F5
05.05.04
Adjust source set
Changeover to source
with Funct.
The source set is adjusted with the keys
UP/DOWN. The copying process is started
with „Enter". Copying is only possible with
opened control release or error, otherwise
„I_oPE" appears in the display (invalid
operation).
After copying „PASS" appears in the display
and could be erase by „ENTER".
All programmable parameters (System parameters too)
of the source set are copied into the target set.
Default values are copied into all parameters of set 0
(with the exception of System and Security parameters).
Default values are copied into all programmable
parameters of the target set (with the exception of Sy-
stem and Security parameters).
Default values are copied into all parameters of all sets
(with the exception of System and Security parameters).
Default values are copied into all parameters of set 0
(with the exception of Security parameters).
Default values are copied into all programmable
parameters of the target set (with the exception of
Security parameters).
Default values are copied into all parameters of all sets
(with the exception of Security parameters).
Parameter Sets
ini_A
ini_S
dEF_A
DOWN
dEF_S
0
1
UP
2
3
4
5
6
7
©
KEB Antriebstechnik, 2002
All rights reserved