Motor Data and Controller
6.6 Motor Data and
Controller
6.6.1
Motor Name Plate
Fig. 6.6.1
Example of a motor name plate
DK 160 L 4 F I
dr.3
3
dr.2
dr.5
50
Hz
ϕ
dr.4
cos
dr.1
U
FL
3
6.6.2
Motor Data DASM
Motor data from name plate
(dr.0...dr.5)
©
KEB Antriebstechnik, 2002
All Rights reserved
The adjustment of the correct motor data is important for many inverter functions,
since calculations are derived from it, which the inverter requires to achieve the
best possible results in the control of Boost and slip compensation.
KEB Antriebstechnik
GmbH & Co. KG
Schneeberg
ANTRIEBSTECHNIK
/TW150
96/1632804/ 001
-Mot IP
55
IM
B 3
VDE 053 0
15,0 KW
230/400
V
0,86
1455
230/400
V
~Mot
50
Hz
M
Br
Following parameters can be taken directly from the name plate of the three-phase
asynchronous motor (DASM) and entered:
- dr.0
DASM rated current
- dr.1
DASM rated speed
- dr.2
DASM rated voltage
- dr.3
DASM rated power
- dr.4
DASM power factor
- dr.5
DASM rated frequency
Parameter dr.0 and dr.2 must always be adjusted in accordance with the used connection
(star or delta). For the above motor name plate it means that it is 230 V / 49,5A for
delta connection and 400 V / 28,5 A for star connection. It doesnít matter that for
example the rated output voltage of the inverter is larger (e.g. Ñ87Hz-chracteristicì).
Name: Basis
KEB COMBIVERT F5-M / S
Functional Desription
Made in
Germany
W.KI.
F
/Y
49,5/28,5
A
1/min
IGR 05B
2500 Imp
5V D0/RS
Nm
I
Sp max
0,0...710,0 A (Star-/Delta-connection)
0...64000 rpm
120...500 V (Star-/Delta-connection)
0,35...400,00 kW
cos(phi) 0,50...1,00
0,0...400 Hz
40
∞C
127
kg
6xTTL
mm
Date
Chapter
Section
6
6
12.05.04
6
dr.0
Page
3