KEB COMBIVERT F5 MULTI Applications Manual page 319

Hide thumbs Also See for COMBIVERT F5 MULTI:
Table of Contents

Advertisement

CP-Parameter Definition
Table 1 Unit
Table 2
Calculation mode
Table 3
Representation
Example
©
KEB Antriebstechnik, 2002
All rights reserved
Value Unit
Value Unit
0 none
16 km/h
1 mm
17 1/min
2 cm
18 Hz
3 m
19 kHz
4 km
20 mV
5 g
21 V
6 kg
22 kV
7 us
23 mW
8 ms
24 W
9 s
25 kW
10 h
26 VA
11 Nm
27 kVA
12 kNm
28 mA
13 m/s
29 A
14 m/s
2
30 kA
3
15 m/s
31 °C
Value
Function
(selected parameter + ud.20) x
0
64
(selected parameter + ud.20) x ud.18
-
free
-
free
Value Representation
0
0 decimal places
256
1 demical place
512
2 decimal places
768
3 decimal places
1024 4 decimal places
1280 variable decimal places
1536 Hexadecimal
-
free
The actual frequency shall be displayed in CP.1 in rpm. Display standardization from
set 4.
ud.15 = 1
ud.16 = 0203h
ud.17 = 4352
Satz 4 ud.18 = 80
Satz 4 ud.19 = 60
Satz 4 ud.20 = 0
Satz 4 ud.21 = 17
Name: Basis
KEB COMBIVERT F5
Functional Description
Value Unit
32 K
33 m
34
35 k
36 INC
37 %
38 KWh
39 mH
40 -
41 -
42 in
43 ft
44 yd
45 oz
46 lb
47 lbft
ud.18
ud.19
; CP.1
; Actual frequency ru.3
; Display in current set, display standardization from set 4
; Conversion from 1/80 Hz into rpm without pole pair number
; no Offset
; Unit rpm; direct calculation mode; no decimal places
04.05.04
Value Unit
48 lbin
49 in/s
50 ft/s
51 ft/min
52 ft/s²
53 ft/s³
54 MPH
55 kp
56 psi
57 °F
58 -
59 -
60 -
61 -
62 -
63 -
The
unstandardized
ud.19
value is always
= CP.xx
used for the
„selected
= CP.xx
parameter" !
Date
Chapter
Section
6
13
6
Page
7

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Combivert f5 servo

Table of Contents