Example - KEB COMBIVERT F5 MULTI Applications Manual

Hide thumbs Also See for COMBIVERT F5 MULTI:
Table of Contents

Advertisement

CP-Parameter Definition

6.13.3 Example

©
KEB Antriebstechnik, 2002
All rights reserved
As an example a user menu with the following features shall be programmed:
1. Display of current actual frequency (ru.3) in the respective set
2. Adjustment of a fixed frequency / fixed value (oP.21) in set 2
3. Adjustment of a fixed frequency /fixed value (oP.21) in set 3
4. Acceleration and deceleration time (oP.28/oP.30) for set 2 and 3
5. Energy saving factor (uF.7) shall be displayed in set 2 with display
standardization 4
1.)
ud.15 = 1
ud.16 = 0203h
ud.17 = 256
2.)
ud.15 = 2
ud.16 = 0315h
ud.17 = 4
3.)
ud.15 = 3
ud.16 = 0315h
ud.17 = 8
4.)
ud.15 = 4
ud.16 = 031Ch
ud.17 = 12
ud.15 = 5
ud.16 = 031Eh
ud.17 = 12
5.)
ud.15 = 6
ud.16 = 0507h
ud.17 = 4097
6.)
ud.15 = 7
ud.16 = -1: off
ud.17 = xxx
Adjust all other parameter sets to „off", so that no indication occurs.
The acceptance of the values takes place only after Power-On-Reset of the operator.
Name: Basis
KEB COMBIVERT F5
Functional Description
; CP.1
; Parameter address for ru.3
; Display in the active set
; CP.2
; Parameter address for oP.21
; Setting in set 2
; CP.3
; Parameter address for oP.21
; Setting in set 3
; CP.4
; Parameter address for oP.28
; Setting in set 2 and 3
; CP.5
; Parameter address for oP.30
; Setting in set 2 and 3
; CP.6
; Parameter address for uF.7
; Setting in set 0 and display standardization 4
; CP.7
; CP.7 not displayed
; ud.17 no function
04.05.04
Date
Chapter
Section
6
13
6
Page
5

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Combivert f5 servo

Table of Contents