KEB COMBIVERT F5 MULTI Applications Manual page 346

Hide thumbs Also See for COMBIVERT F5 MULTI:
Table of Contents

Advertisement

Error Assistance
Display COMBIVIS
A.buS
ABN.STOP bus
A.dOH
ABN.STOP drive over heat
A. EF
ABN.STOP external fault
A.ndOH no A. drive overheat
A.nOH
no A. overheat pow.mod.
A.nOHI no A.STOP overheat int.
A.nOL
no ABN.STOP overload
A.nOL2 no ABN.STOP overload 2
A. OH
A.STOP overheat pow.mod
A.OH2
ABN.STOP motor protect.
A.OHI
ABN.STOP overheat int.
A. OL
ABN.STOP overload
A.OL2
ABN.STOP overload 2
A.PrF
ABN.STOP prot. rot. for.
A.Prr
ABN.STOP prot. rot. rev.
Chapter
Section
Page
9
1
8
Value Meaning
101 The cooling time after "Warning! Overload during standstill"
100 The warning is output when the standstill continuous current
Date
Name: Basis
04.05.04
KEB COMBIVERT F5
93 Warning: Watchdog for communication between operator/
control card or operator/PC has responded. The response to
this warning can be programmed (see chapter 6.7 "Response
to errors and warning messages").
96 The motor temperature has exceeded an adjustable warning
level. The switch off time is started. The response to this
warning can be programmed (see chapter 6.7 "Response to
errors or warning messages"). This warning can be generated
only with a special power circuit.
90 This warning is triggered via an external input. The response
to this warning can be programmed (see chapter 6.7
"Response to errors or warning messages").
91 The motor temperature is again below the adjusted warning
level. The switch off time is stopped.
88 The heat sink temperature is again below the adjusted
warning level.
92 The temperature in the interior of the inverter is again below
the warning
threshold.
98 Warning: no more overload, OL counter has reached 0 %.
has elapsed. The warning message can be reset.
89 A level can be defined, when it is exceeded this warning is
output. A response to this warning can be programmed (see
chapter 6.7 "Response to errors or warning messages").
97 Warning: electronic motor protective relay has tripped. The
response to this warning can be programmed (see chapter
6.7 "Response to error or warning messages").
87 The temperature in the interior of the inverter lies above the
permissible level. The switch off time was started. The
programmed response to this warning message is executed
(see chapter 6.7 "Response to errors or warning messages").
99 A level between 0 and 100 % of the load counter can be
adjusted, when it is exceeded this warning is output. The
response to this warning can be programmed (see chapter
6.7 "Response to errors or warning messages").
is exceeded (see technical data and overload
characteristics). The response to this warning can be
programmed (see chapter 6.7 "Response to errors and
warning messages"). The warning message can only be reset
after the cooling time has elapsed and A.nOL2 is displayed.
94 The drive is driven onto the right limit switch. The response
to this warning can be programmed (see chapter 6.7
"Response to errors and warning messages").
95 The drive is driven onto the left limit switch. The response to
this warning can be programmed (see chapter 6.7 "Response
to errors and warning messages").
©
KEB Antriebstechnik, 2002