Setpoint- and Ramp Adjustment
Fixed-value rotation direction
source (oP.18)
Fixed value input selection 1 and 2
(oP.19; oP.20)
Fixed value 1...3
(oP.21, oP.22, oP.23)
©
KEB Antriebstechnik, 2002
All Rights reserved
With oP.18 it is defined how the direction of rotation is determined in case of active
fixed value. The function and the value range correspond to oP.1.
oP.18 Rotation direction source for fixed values
0
digital via oP.2; setpoint 0-limited
1
digital via oP.2; setpoint absolute
2
terminal strip F/R; setpoint 0-limited
3
terminal strip F/R; setpoint absolute
4
terminal strip Run/Stop; setpoint 0-limited
5
terminal strip Run/Stop; setpoint absolute
6
setpoint-dependent with LS-recognition
7
setpoint-dependent without LS-recognition
8
control word SY.50; 0-limited
9
control word SY.50; 0-absolute
Bit -No. Decimal value Input
0
1
1
2
2
4
3
8
4
16
5
32
6
64
7
128
8
256
9
512
10
1024
11
2048
The three fixed values oP.21...23 are set-programmable and can be adjusted in the
range of -4000...4000 rpm.
Name: Basis
KEB COMBIVERT F5-M / S
Functional Desription
ST (Prog. input ÑControl release/Resetì)
RST (Prog. input ÑResetì)
F (Prog. input ÑForwardì)
R (Prog. input ÑReverseì)
I1 (Prog. input 1)
I2 (Prog. input 2)
I3 (Prog. input 3)
I4 (Prog. input 4)
IA (Internal input A)
IB (Internal input B)
IC (Internal input C)
ID (Internal input D)
Date
12.05.04
Terminal
X2A.16
X2A.17
X2A.14
X2A.15
X2A.10
X2A.11
X2A.12
X2A.13
none
none
none
none
Chapter
Section
Page
6
4
11
6

Hide quick links: