Period Anout3 (An.46); Anout 1; Period Anout3; Digital Settings - KEB COMBIVERT F5 MULTI Applications Manual

Hide thumbs Also See for COMBIVERT F5 MULTI:
Table of Contents

Advertisement

Analog In- and Outputs
Analog output as switch
Computation of the amplification

6.2.15 Period ANOUT3

(An.46)

6.2.16 ANOUT 1...4

Digital Settings

(An.32/37/42/48)
©
KEB Antriebstechnik, 2002
All rights reserved
An example for using the analog output as 0/10V-switch is shown in Fig. 6.2.14.c:
1. adjustment of the amplification (An.33) to 20.00
2. adjustment of the X-Offset (An.34) to the desired switching level
Fig. 6.2.14.c
Analog output as switch
100%
An.34
-100%
-100%
Since the analog output always works firmly onto the values defined under 6.2.10, one
can adjust the characteristic with the aid of the amplification so that the complete
range of 0...±10V is utilized.
defined value
ñññññññññññ = Amplification (An.33 / 38 / 43 / 49)
desired value
Example output frequency
100Hz
ñññññ = 1,47
68Hz
The amount of the selected process variable (An.41/47) is converted into a percentage.
The output of the characteristic amplifier (An.43...45 / An.49...51) is limited to values
from 0...100†%. The multiplication of the base value with the cycle duration (An.46 /
52) results in the ON period of the digital output (selection in do.0..7 value Ñ42/43ì).
The period can be adjusted in a range from 1...240 s.
With these parameters analog values can be adjusted in percent for the respective
input. For that purpose the value Ñ8 digital settingì must be adjusted as process vari-
able. The setting is done within the range ±100 %.
Name: Basis
KEB COMBIVERT F5
Functional Description
10V
Because of the high amplification the
analog output switches in a relative small
An.33
switching window.
100%
Date
04.05.04
Chapter
Section
Page
2
13
6
6

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Combivert f5 servo

Table of Contents