KEB COMBIVERT F5 MULTI Applications Manual page 206

Hide thumbs Also See for COMBIVERT F5 MULTI:
Table of Contents

Advertisement

Functional Description
Hardware current limit (uF.15)
Fig. 6.7.1.b Example for ramp stop function
Used Parameters
R/W
PROG.
Param.
Adr.
Pn.22
0416h
Pn.23
0417h
Pn.24
0418h
Pn.25
0419h
uF.15
050Fh
Chapter
Section
Page
6
7
4
The hardware current limit is an additional, fast protection to prevent faults caused by
overcurrent. Upon exceeding the max. short-time current limit (see Power Circuit
Instruction Manual) the hardware current limit becomes active. The following settings
are possible with uF.15:
0
off; Hardware current limit disabled
1
Single phase mode; Hardware current limit enabled; works both in motoric
and generatoric operation
2
Zero vektor mode; Hardware current limit enabled; works only motoric, but at
activated function it makes available more torque. Generatoric operation
switches to Mode 1.
The hardware current limit limits the current at the limit and triggers no error. This can lead to torque
breakdowns at the motor shaft, which is especially important during the operation „lifting and lowering"
since the drive can sag because of missing torque without the brake engaging.
Acceleration stop
Actual frequency (ru.3)
Inverter status (ru.0)
Actual utilization (ru.13)
Actual frequency (ru.3)
DC-link voltage (ru.18)
Inverter status (ru.0)
Deceleration stop (U)
ENTER
min
0
-
0
4095
-
0 %
200 %
-
200 V
800 V
-
-
0
Date
Name: Basis
04.05.04
KEB COMBIVERT F5
A
C
B
Step
max
default
7
1
1
1
0
1 %
140 %
1 V
375/720 V
2
1
1
Protective Functions
max. ramp current
Pn.24
max. DC-voltage Pn.25
bit-coded
-
% referring to inverter rated current
depending on voltage class
-
©
KEB Antriebstechnik, 2002
All rights reserved

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Combivert f5 servo

Table of Contents