Display COMBIVIS
A.SbuS ABN.Bus synchron
A.SEt
ABN.STOP set
A.SLF
ABN.Software limit switch forward
A.SLr
ABN.Software limit switch reverse
©
KEB Antriebstechnik, 2002
All Rights reserved
Value Meaning
103 Synchronization over sercos-bus not possible. The response
to this warning can be programmed (see chapter 6.7
"Response to errors and warning messages").
102 Warning: set selection: It has been attempted to select a
locked parameter set. The response to this warning can be
programmed (see chapter 6.7 "Response to errors or warning
messages").
104 The target position lies outside of the limit defined with the
right software limit switch. The response to this warning can
be programmed (see chapter 6.7 "Response to errors or
warning messages").
105 The target position lies outside of the limit defined with the
left software limit switch. The response to this warning can
be programmed (see chapter 6.7 "Response to errors or
warning messages").
Name: Basis
KEB COMBIVERT F5
Error Assistance
Date
Chapter
9
04.05.04
9
Section
Page
9
1
9

Hide quick links: