Gtr7-Control - KEB COMBIVERT F5 MULTI Applications Manual

Hide thumbs Also See for COMBIVERT F5 MULTI:
Table of Contents

Advertisement

Protective Functions
6.7.9

GTR7-Control

(not at F5-B)
Output filter
Synchronous motors
Special functions (Pn.65 Bit 0)
Input selection GTR7 (Pn.64)
Parallel connnection of
inverters (DC-
interconnection)
Used Parameters
R/W
PROG.
Param.
Adr.
Pn.64
0440h
Pn.65
0441h
©
KEB Antriebstechnik, 2002
All rights reserved
The GTR7 (brake transistor) serves for the control of the brake resistor.
As a standard the GTR7 is switched in dependence on the DC-link voltage, in order to
discharge fed-back energy. The switching behaviour of the GTR7 can be altered with
the parameters Pn.64 and Pn.65. In the following some applications are specified, at
which the factory setting should be modified.
Output filters, with the contained capacities and inductivities, form an oscillatory circuit
with the motor, thus the drive also operates as generator.
Synchronous motors operate as generator even if the modulation is switched off. .
Especially at low-load systems voltages can be induced, which can lead to the
destruction of the inverter if no attention is paid to it.
The energy fed into the intermediate circuit is transferred over the GTR7 to the brake
resistor. However, as a standard the GTR7 only operates if the inverter modulates.
Generally drives should always be decelerated in a controlled manner.
With parameter Pn.65 the switching behaviour of the GTR7 can be adjusted as follows:
Pn.65 Switching behaviour GTR7
0
1
With Pn.64 an input can be defined for the activation of the GTR7. In this case the
GTR7 switches independent of the inverter status and the DC-link voltage as soon as
the input is active.
Exception: On opening the control release (noP) the inverter must switch off the GTR7
for safety reasons.
Bit -No. Decimal value Input
0
1
2
3
4
5
6
7
8
9
10
1024
11
2048
In a DC-interconnection of inverters the occurring braking energy can be distributed
onto different inverters with brake resistor. With Pn.64 an input at the corresponding
inverter can be defined over which the activation of the GTRs is synchronized.
ENTER
min
-
-
0
4095
-
-
0
Name: Basis
KEB COMBIVERT F5
Functional Description
not in status „LS" (default)
also switches at „LS"
1
ST (Prog. input „Control release/Reset")
2
RST (Prog. input „Reset")
4
F (Prog. input „Forward")
8
R (Prog. Input „Reverse")
16
I1 (Prog. Input 1)
32
I2 (Prog. Input 2)
64
I3 (Prog. input 3)
128
I4 (Prog. input 4)
256
IA (Internal input A)
512
IB (Internal input B)
IC (Internal input C)
ID (Internal input D)
Step
max
default
1
0
7
1
0
Terminal
X2A.16
X2A.17
X2A.14
X2A.15
X2A.10
X2A.11
X2A.12
X2A.13
-
-
Datum
Kapitel
Abschnitt
6
7
04.05.04
6
none
none
none
none
Seite