ru.21
Input terminal state
Adr.
0215h
Display of the current set digital inputs. The logic levels on the input terminals or on the internal inputs are indicated
regardless whether the input is inverted or the internal acceptance is effected through edge-triggering or Strobe (also
see Chapt. 6.3 ÑDigital inputsì). According to following table a specific decimal value is given out for each digital input.
If several inputs are controlled, the sum of the decimal values is indicated.
Bit -No. Decimal value
0
1
2
3
4
5
6
7
8
9
10
11
ru.22
Internal input state
Adr.
0216h
Display of the currently set external and internal digital inputs. The input is considered as set when it is available as
active signal for further processing (i.e. acceptance by strobe, edge triggering or logic operation). According to the table
(ru.21) a certain decimal value is given out for each digital input. If several inputs are set then the sum of their decimal
values is displayed (see Chapter 6.3 ÑDigital Inputsì).
Chapter
Section
Page
6
1
10
min
max
0
4095
Input
1
ST (prog. input Ñcontrol release / resetì)
2
RST (prog. input Ñresetì)
4
F (prog. input Ñforwardì)
8
R (prog. input Ñreverseì)
16
I1 (prog. input 1)
32
I2 (prog. input 2)
64
I3 (prog. input 3)
128
I4 (prog. input 4)
256
IA (internal input A)
512
IB (internal input B)
1024
IC (internal input C)
2048
ID (internal input D)
min
max
0
4095
Date
Name: Basis
KEB COMBIVERT F5-M / S
12.05.04
Operating and Unit Data
default
-
1
-
Terminal
X2A.16
X2A.17
X2A.14
X2A.15
X2A.10
X2A.11
X2A.12
X2A.13
none
none
none
none
default
-
-
1
©
KEB Antriebstechnik, 2002