Rotation Source Op.1; Fixed Values (Op.18; Fixed Values - KEB COMBIVERT F5 MULTI Applications Manual

Hide thumbs Also See for COMBIVERT F5 MULTI:
Table of Contents

Advertisement

Functional Desription
6.4.4

Fixed values

(oP.18...23)
Fig. 6.4.4
Fixed values
Input
Fixed value 1
oP.19 Input selection
Fixed value 1
0...4095
(according to table)
Fixed value 1
oP.21:
-4000...4000 rpm
Fixed value 3
oP.23: -4000...4000 rpm
Selection of fixed value
Chapter
Section
Page
6
4
10
The KEB COMBIVERT supports up to 3 fixed values for each parameter set,
which can be selected via two digital inputs. With oP.19 and oP.20 the inputs required
for the selection are defined (also see ÑDigital inputsì Chapt. 6.3.10). The rotation
direction source for fixed value mode is defined with oP.18. The adjustment is
independent of oP.1 and is valid exclusively for the fixed values. The adjustment of
a fixed value has priority over the Ñnormalì setpoint adjustment.
Digital
Input
0-lim. abs. 0-lim. abs.
Fixed value 2
oP.20 Input selection
Fixed value 2
0...4095
(according to table)
Fixed value 2
oP.22:
-4000...4000 rpm
Setpoint limits
Fig. 6.4.4.a Selection of fixed values
Date
Name: Basis
12.05.04
KEB COMBIVERT F5-M / S
Setpoint- and Ramp Adjustment
Terminal strip
Terminal strip
For / Rev
Run / Stop
oP.2
0-lim.
3
2
1
0
Input fixed value 1
Input fixed value 2
Fixed values f1...f3
Setpoint-
DRIVECOM
dependent
abs.
LS no LS
0-lim. abs.
4
5
6
7
8
9
oP. 18
Fixed value
rotation direction source
Setpoint
f3
f2
f1
©
KEB Antriebstechnik, 2002
All Rights reserved
SY.50
t